DK-LOK CO, Ltd.
625-3,
Nongso-ri, Juchon-Myeon, Gimhae-si,
South Korea 621-842
Phone:
(82) 055-338-0114 •
Fax:
(82) 055-901-0143
E-Mail:
sales@dklok.com
•
Web site:
www.dklok.com
All Categories
>
Compression Tube Fittings
>
Tube Stub Connectors
>
DAM-N Male Adapter Tube Fittings Metric
>
DAM-N Male Adapter Tube Fittings Metric
>
Item # DAM-6M-2N-C
Item # DAM-6M-2N-C, DAM-N Male Adapter Tube Fittings Metric
larger image
larger image
Specifications
·
Dimensions
·
Instalation Instruction
Specifications
Z Series Ferrule
No
Material
Carbon Steel
Moly Coating
None
Dimensions
Line Drawing
DAM-N Male Adapter Tube Fittings Metric-2
Thread Type
PT
T - Thread Size
1/8
E - Min.
4.6
mm
E1 - Min.
4.6
mm
h - Width Across Flat
12.0
mm
l
15.7
mm
L
32.8
mm
Instalation Instruction
1. Insert the tube stub end into the Dk-Lok port
Make sure that the tube stub end bottoms on the fitting body shoulder.
2. Spanner-tighten the nut 1 1/4 turns beyond the finger tight position.
Tighten the nut 3/4 turn for 1/8, and 3/16 in.; 3, and 4 mm tube fittings.
Note: For re-use, see re-assembly instruction.